Moisture meter use matters needing attention

    Moisture meter use matters needing attention Moisture meter is a commonly used instrument, which has a wide range of applications and a large role. It is also a kind of precision instrument. Therefore, the following six points must be observed when using the moisture analyzer.

    The first is that when the moisture analyzer is in use, the system must be fully enclosed. The connection of the Karl Fischer reagent fluid circuit of the moisture analyzer must be fastened, from the reagent bottle to the metering pump to the reaction cell, otherwise reagent leakage will occur directly. Affect the test results. If the system is not sealed, the other problem is that the Karl Fischer reagent absorbs air moisture during the test, which can cause a delay in the titration end point.

    The second is that the sampling should be accurate. Generally speaking, it is necessary to use 10mg of water, so try to use a 10ul sampler. This is also true for the methanol reagent and ethyl ester. Because this is not only accurate and fast, it also prevents water droplets from adhering. After the picking and placing is completed, attention should be paid to shortening the opening time of the reaction pool as much as possible.

    The third is the magnetic stirrer speed adjustment: In the reaction tank, because the titration reagent is added locally, it is not in the same place as the electrode. Therefore, the stirring speed is preferably fast enough to not form a turbulent flow so that the end point can be reached as quickly as possible.

    The fourth is that the titration speed must be set quickly and slowly beforehand, and the titration should be performed quickly to shorten the test time as much as possible, and to be slower when approaching the end point, which can improve the measurement accuracy.

    The fifth is that after each test, the Karl Fischer reagent in the system must be emptied and then cleaned with methanol. Do not wash the system with water because it will not evaporate easily, which will cause Karl- Fischer reagent calibration is false. Cleaning with methanol will ensure the accuracy of the measurement.

    The sixth is that in daily life moisture analyzers should be kept away from strong magnetic fields to avoid electronic display jitters and abnormalities during work. Especially for manual moisture meter, because it is necessary to use a glass burette automatic metering Karl - Fischer reagent and methanol solvent, and a glass burette itself because of the equilibrium pressure, but also must be connected with the outside world.

    Plastic Window Screen

    Plastic Window Screen,Screen For Laptop Windows,Window Led Screen,Plastic Anti Fly Insect Screen Windows

    HEBEI CONQUER HARDWARE WIRE MESH CO.,LTD , https://www.conquerwiremesh.com

    Previous Post: Iron ore beneficiation test plan example
    Next Post: Weichai Power Ranked in the “Haodao Lushang” Brand List
    Home
    Recent Posts
    • The main multi-function picking performance Baod…
    • The status quo of the "three rates" of…
    • Recycling volume exceeds 250,000 tons in 2020 Wa…
    • Full height cross brake structure and its workin…
    • The basic principle and process of gold extracti…
    • Four-way frequency converter in ball mill applic…
    • Intelligentization will become one of the develo…
    • Teach you how to choose a tire
    • Car parts companies seek financing for long-term…
    • MIM Stainless Steel Password Fingerprint Manufac…
    • US luxury car market differentiation
    • The development of precision instruments in our …
    • The Shandong Provincial Science and Technology P…
    • What you need to know about Poodle
    • Buy used cars to do the maintenance of these 7 m…
    • 2000bph Pet Drinking Beverage Water Bottle Plast…
    • China Agricultural Machinery and Parts Exhibitio…
    • Do you understand these safety requirements when…
    • What is the specific magnetic susceptibility of …
    • What is the role of pulp mixing?