Causes high and low temperature alternating heat and humidity test chamber equipment alarm reason

    Causes high and low temperature alternating heat and humidity test chamber equipment alarm reason

    In most cases, equipment alarms are caused by improper operation of the operator during the use, mainly including three reasons: refrigeration system, temperature system and fan system.

    1. Refrigeration system of high and low temperature alternating heat and humidity test chamber

    1. Refrigeration compressor overpressure alarm. If the refrigerant pressure of the refrigeration system exceeds the set value, it will stop and alarm at the same time. At this time, it is necessary to eliminate the fault and then perform manual reset.

    2, power phase loss, phase sequence alarm. When the external power supply of the device is out of phase or the phase sequence is changed, it will stop and alarm at the same time.

    3, circulating cooling water shortage alarm. When the water pressure in the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait until the fault is eliminated and reset before it can operate normally.

    4. Refrigeration compressor overheat alarm. When the coil of the compressor is overheated and the power supply of the line is abnormal, it will stop and alarm.

    Second, high and low temperature alternating heat and humidity test chamber temperature system

    1. Over temperature alarm in the box. The sensors in the channel and in the sample area are equipped with over-temperature protection devices, and the operation panel also has an over-temperature protection device. When the temperature in the test area exceeds the temperature set on the panel, it will stop and alarm.

    2. The sample is over temperature protected. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm. The over-temperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set as needed.

    Third, high and low temperature alternating heat and humidity test chamber fan system

    1. The fan overheats to cause an alarm. When the coil of the fan is overheated, it will stop and alarm.

    2. Fan over-current alarm. When the current of the fan exceeds the allowable value, it will stop and alarm at the same time, and it will not be able to operate normally until the over-current troubleshooting is completed.

    Electric battery driven Refrigeration Unit

    Rooftop Cooling Units,Cooling Unit For Truck Freezer,Rooftop Refrigeration Unit,Electric Refrigeration Unit

    XINXIANG HUATAI REFRIGERATION CO., LTD , https://www.trustht.com

    Previous Post: Deep hole processing benefits from trace oil mist lubrication technology
    Next Post: Full ¥666 reduction ¥99! There are 3 chain rail limited time specials!
    Home
    Recent Posts
    • Tl5002 Security Serial Number Meter Seal Crimpin…
    • Modern Design Vegetable Brush Washing Peeling Ma…
    • Bead Embroidery Machines/ Industrial Automatic P…
    • BICES 2019 | The new generation of CAT® equipme…
    • Energy-efficient and efficient cooperation betwe…
    • Deep hole processing benefits from trace oil mis…
    • Causes high and low temperature alternating heat…
    • Full Â¥666 reduction Â¥99! There are 3 chain rai…
    • Explosion-proof ball machine is different from g…
    • John Deere Construction Machinery, a good helper…
    • Community-specific gas detector installation pre…
    • What is the scan code access control? What are t…
    • Provincial, Oil and Environmental Protection Wet…
    • Smart environmental protection pioneer Liugong f…
    • Discussion on the improvement and application of…
    • Graphic Doosan DX65-9C PLUS
    • Daily maintenance and troubleshooting of pumps
    • Xichai takes the needs of card friends as the ce…
    • Radar level gauge and guided wave radar level ga…
    • Huizhou indoor fixed freight elevator freight el…